Issue of connecting the wall air barrier assembly to other building assemblies such as below grade window systems and roofs need to be completely understood in order to design and construct a functioning building enclosure.
Pitched roof vapour barrier.
Looking for pitched roof materials.
Where high water vapour resistant type hr underlay e g.
However note that one should seal the seams here as well.
Including flat roof vapour barrier for extra secure roofing solutions.
Insulating a pitched roof space.
Tyvek membranes are specially designed to minimise interstitial condensation and remove the need for ventilation in the insulation providing a holistic solution to energy efficient warm pitched roof constructions.
Bituminous vapour retarders asphalt mixed with felt or fiberglass or non bituminous vapour retarders plastic laminate or aluminum coated.
Flat roof vapour barrier materials when constructing a flat roof there are two types of materials commonly used.
They permit water vapour in the roof space to permeate through to the batten space where the natural movement of air through the roof covering disperses it into the atmosphere.
This removes the need for ventilation in the insulation a benefit that is particularly important with cold pitched roof construction.
A flat roof vapour barrier such as iko s mvp modified vapour protector offers appropriate moisture protection.
With all the insulation board in place start at the top of the roof and fix the vapour barrier to the rafters using a staple gun fold the barrier material into a sort of z at each rafter so that the staple goes through a double thickness.
If the roof covering or roof membrane is a material of high moisture resistance or impermeable then the building regulations require a 50mm wide ventilation gap beneath the roofing felt and tiles.
I have recently finished installing a celotex warm roof to my house i have several sheets left over my flat roof extension needs to be recovered and insulated also as a warm roof can i use the 100 mm ga 4000 insulation boards i have left over for this project if so would i need to use a vapour control barrier or would taping the joints act as a vapour barrier the roof surface will be.
The ventilation requirements of a pitched roof depends on the type of roof membrane used under the tiles or slates and battens to keep moisture or rainwater coming in from outside.
You ll find pitched roofing products here.
They permit water vapour in the roof space to permeate through to the batten space where the natural movement of air through the.
The roof is covered with high water vapour resistant type hr underlay and the pitch exceeds 35 or the span exceeds 10m this is in addition to eaves ventilation.
Next to that you may also buy a moisture regulating vapour barrier membrane that can manage the damp even better.
If the roof is insulated with foil faced insulation blankets the aluminium side can serve as a vapour barrier at the same time.