Restaurant function room if used as a dining room 85m 2 1m 2 per person 85 persons.
Room capacity fire regulations uk.
The maximum number of persons it is designed to hold.
Evaluate remove reduce and protect from risk.
Provides guidance on general fire safety advice completing your fire risk assessment and how to calculate safe occupancy figures.
Persons regardless of the width of the exit see table 2 60 people is also the limit for an exit where the door opens inwards.
Identify people at risk.
Fire risk assessment and the five steps to risk assessment.
Bar 30m 2 0 5m 2 0 3m 2 within 1m of the bar per person 60 persons.
Buildings other than dwellinghouses defines the occupant capacity of a room storey building or part of a building as.
However the occupancy will be lower if there are a number of obstructions such as tables columns or couches.
If only one exit is available from a room then the maximum capacity is 60 persons regardless of the width of the exit.
As with the building regulations the british standards guidance assumes that if a storey has two or more storey exits a fire might prevent the occupants from using one of them.
Finally calculate the total exit capacity after discounting the largest exit or exits in the case of ones that are close together as the fire may affect an exit in this case 2 exits for 200 persons each are close together so their total is discounted 700 400 300 persons total exit capacity.
So the premises capacity is for the restaurant used as a function room will be.
Most people have noticed when dining in a restaurant or staying in a hotel room that there is a maximum occupancy limit for the space.
When calculating the exit capacity then if a room has two or more exits it has to be assumed that a fire might prevent the occupants from using one of these exits.
An exit consisting of a double door is regarded as one exit.
This is usually quoted as being ordered by a fire marshal just what goes into determining the maximum occupancy of a room.
Maximum capacity is 60.
Therefore the remaining exit s need to be wide enough to allow all the occupants to leave quickly.
The building regulations approved document b2 fire safety.
170 60 100 330 persons.
Is available from a room then the.
This must be in writing 1.